Controlling Fire Growth in Electrical Cable Compartment by Reducing Oxygen Concentration at Horizontal Orientation

Authors:
Adrianus Pangaribuan, Fadhil, Muhammmad Agung Santoso, I Made Kartika Dhiputra, Yulianto Sulistyo Nugroho

Abstract

A series of laboratory tests for electrical fires have been carried out by researchers, and some of the results have confirmed and been adopted as standard. However, the studies focus on electrical fires in PVC insulation material and the melting temperature and toxicity of PVC insulation. By focusing on heat conductors, the growth and spread of a fire can be eliminated by reducing the oxygen concentration, especially inside the compartment. Electrical fires are the most common cause of compartment and building fires both internationally and nationally, according to statistics (Liu & Benichou, 2008). Whatever the triggers are inside the electrical compartment on the connection, termination, or cable, this research looks into electrical fires caused by 1.0–1.5 mmsq electrical cables. Electrical fires in cables are normally started by increasing temperatures inside the cable conductor. By controlling and adjusting the oxygen concentration inside the electrical compartment under atmospheric concentration, one can hamper a fire’s start, trigger, propagation, and growth. This study investigates the effectiveness of oxygen concentration on preventing the growth of fires triggered by electrical cabling. A series of studies were created in laboratory scale in a horizontal compartment with oxygen levels of 19%, 17%, and 15%. This paper presents the results of this experiment by studying the effects of reducing oxygen concentration on the fire growth in cable network in a horizontal orientation. The results show that controlling the oxygen concentration at levels lower than atmospheric concentrations can effectively reduce the propensity for cable ignition and lower the fire propagation rate.

Keywords: Cable fire Electrical fire Electrical fire prevention Oxygen controlling Oxygen reduction
DOI: https://doi.ms/10.00420/ms/0318/JK088/JHR | Volume: 7 | Issue: 2 | Views: 0
Download Full Text (Free)
Article Document
1 / 1
100%

Subscription Required

Your subscription has expired. Please renew your subscription to continue downloading articles and access all premium features.

  • Unlimited article downloads
  • Access to premium content
  • Priority support
  • No ads or interruptions

Upload

To download this article, you can either subscribe for unlimited downloads, or upload 0 items (articles and/or projects) to download this specific article.

Total: 0 / 0
  • Choose any combination (e.g., 2 articles + 1 project = 3 total)
  • After uploading, you can download this specific article
  • Or subscribe for unlimited downloads of all articles